Macpower Alumni Manuál s instrukcemi Strana 27

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 74
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 26
SVAT ELECTRONICS
now you can see
CLEARVU11
24
MAIN MENU
The general operations are as below:
• ▲▼◄►- Press these buttons to select the items. The display will scroll left/right if the selected item is not
shown on the screen.
• Numeric (CH1-CH4) - Press these buttons to select the camera.
• COPY ( ) - Press this button to copy all the settings - excluding detailed Motion settings, Video Loss
settings, Title/Audio - of the focus camera to all the following cameras. (E.g. focus camera is 1, its settings will
be copied to those of cameras 2-4.)
• ESC(MENU/ESC)-Press this button to escape from this screen, and return to Setup Menu display. If the Save
dialog is shown, press ENTER to exit and save, ESC (MENU/ESC) to exit without saving.
ALARM SETUP
In Setup Menu display, press ▲▼
to change the highlighted option
to Alarm, and then press ENTER
to call up Alarm Setup display as
shown. The Alarm Setup allows
the administrator to dene the
attributes for each alarm input, and
the actions if it’s triggered. There
are up to 4 alarm inputs which can
be connected to the system.
Following is a brief description for each item and its specic operations:
• Normal State – press +/- buttons to select N/A, Close or Open. Please check the signal type, normally close or
normally open, connected to the alarm input terminal on the rear panel of the system. If theres no signal connected,
please select N/A Not Available, and the following items will not be setup. The default setting is Open.
• Focus Camera – the camera corresponding to this alarm input.
• Duration response duration to dene how long (in seconds) the Alarm Out relay and the Buzzer will stay on for
after this alarm input is triggered. However, the Alarm Out relay and the Buzzer will be reset immediately once this
alarm input returns to normal. Press +/- buttons to adjust the value (3-60 seconds, discrete).
• Goto Preset – to dene the preset position to go to for the Focus Camera if this alarm input is triggered (only
available for PTZ cameras).
• Pre-record – to dene how long before this alarm input is triggered the Focus Camera will be recorded at pre-
record IPS. Press +/- buttons to adjust the value (0-10 seconds, discrete). Please note that the actual pre-record
time may be shorter than the value set if the total size of the pre-record pictures exceeds the pre-record buer size
of the system.